Dynamics | |
---|---|
Frequency Response | 0.1 to 2,500Hz (<±3dB) |
Measurement Range | ±50g (<±5%) |
Sensitivity | 20mV/g (<±5%) |
Resonant Freuency | 22KHz |
Resolution | 0.024g |
Transverse Sensitivity | ≤ 5% |
Excitation Voltage | 3.3VDC |
Output Bias Voltage | 1,650mV |
Full scale Output Voltage | 1,650mV ± 1,000mV |
Case Isolation | > 100 MΩ |